Power services offers a wide range of
electrical control devices. AMF relay is one of them. AMF relay is
designed to make AMF panel reliable, simple & easy to operate. It
has built in Mains voltage sensor, incoming delay timer, starting
attempt timer with ON & OFF delay, 3 attempt & lock, DG voltage
sensors, counters, logic control, etc. Opto couplers isolate
incoming high voltage supplies & output connections are through
electromechanical relays. It does not require any separate power
supply & works on DG set starting battery.
Specifications
Aux. Supply-12/24V DC, Sens.
Mains- 3 Phase 4 Wire, under voltage, Single phasing,
Mains incoming delay- 30-60
secs. (Adjustable), Start signal-ON time 3-6 sec.
(adjustable), OFF time-3-6 sec., 3 attempt & lock, ideal
running-30-60 sec.(adjustable), Stop solenoid timer-30-60sec.(adjustable),
logically interlocked, Isolation- optically isolated for
mains, DG, electromechanical relay for output, Contact
rating- 5Amps, terminals- PCB mounted for 2.5 Sq.mm wire,
Indications- Mains, Starting attempt ON time, Set fail to
start, DG set low voltage, Load ON DG, Load ON mains. |
|
POWER HOUSE offers Engine
Protection Relay that protects the engine from
a) Over speed
b) Low oil pressure
c) Low fuel
High radiator temperature.
It has an electronic protection system
that gets input from various sensors of speed, oil pressure, fuel
level & radiator temperature. These inputs are constantly monitored
& compared with their respective limiting values. The moment any one
or more parameters crosses their limit, separate LED indicator
glows, hooter actuates & a timer (30-60secs.) starts to stop the
engine.
Specifications:
Aux..supply: 12/24V DC,
Sensors: High speed: Generator
frequency(single phase output from
alternator).Built in.
Low oil pressure:
Pressure switch type(N/O).
Low fuel: Float
switch type (N/O).
High radiator
temperature: Bi-metallic Thermostat (N/O).
Output: Hooter: 1 change over
(potential free).
Stop solenoid: 1
change over (potential free).
Timer: For stop solenoid built in.
LED indication: 1) Aux supply
2) Alt.
Supply
3) Stop
Solenoid
4)
Engine over speed.
5) Low
oil pressure.
6) Low
fuel level.
7) High
radiator temperature.
Mounting: Flash.
Enclosure: ABS mould.
Dimensions: 96x96x130 mm
Cut out: 92 x 92 mm
Reset: Red push switch – accept.
Green push switch –
reset
Cascading: External switch for stop solenoid timer
|
NURSES CALL
MONITORING SYSTEM
|
Power House offers the latest solid
state call monitoring system most suitable for Hospitals & Nursing
homes. Some of the features that are not available in other
conventional systems are: -
1) Low voltage operation-The incoming
mains are converted to 12V D.C & patient is not put to danger even
due to accidental snatching of wires.
2) Battery back up-The calls can even
be make during power cut as it is provided with battery back up.
3) Detachable call PUSH-Call points
are made of soft push buttons with flexible cord & detachable plug.
4) Re-set at patient bed-The nurse or
attendant has to press a button installed near the patient ensuring
attendance.
5) Built in timer-Each call received
activates a built in timer & after a specified time, triggers a
separate buzzer to draw attention of matron. The buzzer is silenced
only after attending the patients.
6) Unattended call-Through change of
color of indicators (green to red) matron will identify the
unattended call.
7) Soft buzzer-Soft tone buzzers
ensure no disturbance in the hospitals/nursing home.
8) Compact & flexible-The system
requires very low space& is flexible to add on as the number of beds
increases.
This unique system is designed with utmost reliability,
dependability & safety features in mind.
|
WELDING
TRANSFORMER CONTROLLER
|
POWER HOUSE offers an unique device
Welding Transformer Controller (WTC) introducing a new concept
in electricity saving for arc welding operation. The welder keeps
the transformer ‘ON’ from beginning to end of the day but actual
welding process is carried out only for a fraction of total “on”
time as he also have to make arrangement for weld. POWER HOUSE
welding transformer controller switches ‘OFF’ the transformer when
welding is not taking place. To start the welding, the welder
touches the electrode to ground level (job), which shorts the
secondary of welding transformer. This is sensed by the controllers
built in electronic circuitry & remains ready for switching ON the
contactor to energize primary of the welding transformer. While
welder continues welding, the controller senses the process & keeps
the primary energized. Controller has an in-built timer that
switches off the contactor if there is no welding for 30 seconds.
Per month saving =
415V x 6A x 0.5 x 6hrs x 25days x Rs4/- = Rs.747/-
(6A is the average no load current
that the welding transformer consumes even while the welding is not
carried on).
Salient features:
 |
It doesn’t affect the quality of
welding. |
 |
Easy to install & use. |
 |
Improves system p.f. |
 |
Recovers the cost in less than 6
months. |
 |
Reduces maintenance. |
 |
Auto/Manual option. It is compact. |
 |